7/ EVERYDAY MAINTENANCE
Your EuroCave wine cabinet is an appliance with tried and tested performance.
Maintenance operations to be carried out every 3 months
Remove the 2 screws from the grille with a no. 2 hexagonal spanner (provided int the accessories bag).
Remove the grille, take out the filter and place under running water.
Leave to dry and refit the assembly.
Maintenance operations to be carried out approximately once a
year
Unplug and unload the appliance.
Clean the water drain at the bottom of the wine cabinet. Pay attention that nothing is blocking this drain.
Clean the inside of the compartments with water and a gentle cleaning product.
Rinse thoroughly. Dry it with a soft rag.
Replace the active carbon filter housed in the upper ventilation hole in your cabinet (see chapter 6, § VI).
Manually remove the carbon filter. It is available from your usual dealer. It must be replaced using a
manufacturer guaranteed part.
Check that the door seals are in good condition. It is often necessary to clean the door seal. Using
unsuitable cleaning products can cause premature ageing of the seals. Certain rules must therefore be followed: whenever you clean the seal, always rinse off
any cleaning product with clear water. All traces of cleaning product must be removed from the seal. EuroCave only recommends using a mild soapy solution.
If this proves insufficient, it is possible to occasionally use an ethanol-based solution, provided that the concentration used is less than 10% and that the seal
is then rinsed thoroughly with clear water.
8/ OPERATING FAULTS
Possible incidents
Causes
The temperature
The icon
displays
has not dropped
below the limit of
±4°C / 39°F
Operating faults
The icon
is still displayed even
though I have performed the corrective
action above
Open door alarm Ensure the door is closed properly.
The icon
displays
The relative
The icon
flashes
humidity rate
falls below 65 %
for more than 72
hours
The apparatus cannot lower the humidity
to the desired level.
Carbon filter
The icon
displays
alarm
Temperature
The icon
displays
sensor defect
alarm
/
The wine cabinet does not switch on.
Minimum duration of guarantee offered by the manufacturer: 2 years parts.
18
GB
If your appliance appears to be functioning abnormally, contact your EuroCave dealer.
1
2
Your appliance is equipped with a frost prevention
device to protect you in the event of a cold circuit
failure.
Corrective action
Check the door is closed properly.
Check the condition of the door hinge.
If you have placed a large number of bottles in your cabinet in the past few hours,
wait a short while then check the temperature again..
If the alarm persists, contact your EuroCave dealer.
Disconnect the cabinet and contact your EuroCave dealer.
Add a glass of water on the humidity cassette (see chapter 6, § IV).
In order to obtain the time interval for adding water, count the number of days
between the 1st day when water was added and the day when the pictogram was
displayed.
After a few hours the icon will go out.
Empty the cabinet, remove the humidity cassette and clean the tank.
Adjust the level of humidity to 75 % but do not install the pozzolana cassettes
or replace them with new ones.
Call the EuroCave dealer if the problem persists despite these different actions.
Replace the carbon filter (see chapter 6, § VI).
Contact your EuroCave dealer.
Contact your dealer/EuroCave after-sales service.
9/ TECHNICAL FEATURES AND ENERGY DATA
Compact 59
Height
Width
mm
mm
1 temperature
V059
830
595
V259
1790
595
Multi temperature
S059
830
595
S259
1790
595
Setting accuracy: +/-1°C/ 2°F, Display accuracy: +/- 1 °C/ 2 °F.
According to delegated regulation (EU) 2019/2016 of the European Commission, access energy data about our appliances on the EPREL database by scanning
the QR code visible on your appliance's energy label.
Data relating to American energy consumption regulations
R
Model
efeRence
V-059V3
Single temperature
V-059V3
Single temperature
V-259V3
Single temperature
V-259V3
Single temperature
S-059V3
Multi temperature
S-059V3
Multi temperature
S-259V3
Multi temperature
S-259V3
Multi temperature
1
Comply with DEPARTMENT OF ENERGY - 10 CFR Part 430 - Energy Conservation Program: Energy Conservation Standards for Miscellaneous Refrigeration Products.
Standards
Your product complies with the following standards:
1 SAFETY DIRECTIVE 2006/95/EC
Standards EN60335-1 : 2012+ A11 : 2014
EN60335-2-24 : 2010
2 EMC 2004/108/EC
Standard EN55014-1/2
Standard 62233 :2008
3 ENVIRONMENT
Directive 2010/30/EU
Regulation 1060/2010
Depth
Weight when
Recommended temperature range
mm
empty kg
T° mini °C / °F
570
42
0 / 32
585
65
0 / 32
570
40
12 / 54
585
63
12 / 54
United States
115V 60Hz - R600a gas
Type of door
Annual energy consumption
kWh/yr
Solid Technical Door
Glass and Full Glass door
Solid Technical Door
Glass and Full Glass door
Solid Technical Door
Glass and Full Glass door
Solid Technical Door
Glass and Full Glass door
R600a
According to the country, EuroCave wine
cabinets contain a flammable refrigerant
gas (R600a: ISO BUTANE)
T° max °C / °F
30 / 86
30 / 86
30 / 86
30 / 86
1
172
172
212
212
172
172
212
212
19