(b)
5
– Overturn the air intake (b) and replace
the seal (5) with the seal supplied in the
kit code 8089904;
– Insert the intake diaphragm supplied in
the kit code 8089904, pushing it in until
it is in contact with the beat.
You can now insert the extension or curve
in its housing to complete the intake (you
need not use any seal or sealant).
KEY
1 Separate flue kit code 8089904
2a 90° elbow MF (n° 6) code 8077410
2b Isolated 90° elbows MF code 8077309
3a Extension L. 1000 (n° 6) code 8096003
3b Insulated extension L. 1000 code 8077306
3c Extension L. 500 (n° 6) code 8077308
4 Outlet terminal code 8089501
5 Int.-est. ring kit code 8091500
6 Intake terminal code 8089500
7 45° elbow MF (n° 6) code 8077411
8 Condensation outlet L. 135 code 8092800
9 Doubler fitting code 8091400
10 Tile with articulated joint code 8091300
11 Roof outlet terminal L. 1390 code 8091201
12 Tee condensation outlet code 8093300
IMPORTANT: In type C52 the outlet and inlet flues must not come out on opposite walls.
80
IMPORTANT: The three housings on
(a)
the diaphragm permit assembly of the
air intake in one position only.
2.9.2
Outlet systems
The diagrams in fig. 10/a illustrate a num-
ber of examples of different types of sepa-
rate outlets.
2. 1 0
FORCED EXHAUST (Type B22-52)
Comply with the following requirements
3
2
1
C42
during installation:
– Insulate the exhaust pipe and install a
condensation collection system at the
base of the vertical pipe.
– If the pipe passes through combustible
walls, insulate the section of the flue pipe
passing through the wall with a 30 mm
thick fibreglass pipe covering with a den-
sity of 50 kg/m
In "25-30 Solar" models this type of exhaust
pipe is installed using the special kit, code
8089904. For kit assembly instructions,
refer to point 2.9. 1 . Protect the intake with
the optional accessory, code 8089501.
The accessory is assembled by cutting a 50
mm long segment from an ordinary ø 80
Fig. 10
extension and inserting it on the air intake,
on which the accessory is then fitted, ancho-
red to the pipe segment with the screws pro-
vided (fig. 11). Kit code 8089904 is supplied
with the intake diaphragm, which must be
used as shown in fig. 9/a, depending on the
maximum permitted flow. Maximum flow
resistance must be no more than 7.6 mm
H
O in vers. "25 Solar" - 9 mm H
2
"30 Solar". As the maximum pipe length is
determined by adding up the flow resistance
of the various individual accessories instal-
led, refer to Table 1 for calculation.
11
10
9
3
7
3
3
8
2
1
3
1
C32
C52
B52
3
2
3
8
3
3
1
2
C82
3
B22
1
C12
B52
3
.
O in vers.
2
11
10
3
12
6
6
4
5
max 0,5 m
6
Fig. 10/a