working field with heating plant functio-
IT
ning.
ES
– Other faults (fig. 27/b)
- If orange indicator light comes on (SM
probe fault), turn off the boiler and con-
PT
tact your authorised technical service
centre.
GB
- If red/orange indicator light comes on
(problem in the solar temperature sen-
sor ST), turn off the boiler and contact
your authorised technical service centre.
- If the green flashing indicator light
comes on (fan fault/exhaust pressure
switch), turn off the boiler and contact
your authorised technical service centre.
- If the flashing orange light comes on (no
water circulation), turn the boiler off and
then turn it on again to restore functio-
ning. If the indicator light comes on again,
turn off the boiler and request assistance
from an Authorised Technical Service
Centre.
- Version "OF ES":
If the green flashing indicator light comes
on (exhaust thermostat tripped), to begin
functioning again, reset the exhaust ther-
mostat button. If the device is tripped fre-
quently, contact your authorised techni-
cal service centre.
If the flashing orange light comes on
(insufficient water pressure), restore
functioning using the filling tap (fig. 27/a).
If the flashing red indicator light comes on
(fault in SS probe), turn off the boiler and
request the assistance of an Authorised
Technical Service Centre.
- If the boiler and the green voltage LED
switch off, it is possible to reset the unit
by disconnecting it from the mains for a
few minutes and by pressing the main
switch on the outside of the boiler.
92
Scala
colore
IT CLIMBS
30
azzurro
BLUE (1) COLOR
°C
0
4
3
2
60
90
Scala
120
IT CLIMBS
colore
bar
0
BLUE
blu
3
1
(2) COLOR
3
4
2
5
Apre
OPEN
4
5
Fig. 27/a
Fig. 27/b

Publicidad

loading

Este manual también es adecuado para:

Format.zip 30 solar