Operating hours of hot-water generator
1
Operating hours of ultra-fine filter (WSO)
2
Note
The menu with the operating hours of the washing pro-
grammes is structured according to the same principle.
Menu Maintenance Diagnostic
The Maintenance Diagnostic menu shows the times un-
til the next maintenance, system information, error mes-
sages and events.
"Event History" menu button
1
"Fault History" menu button
2
"System Information" menu button
3
"Interval" menu button
4
Menu Interval
In the Interval menu, the time until the next maintenance
is displayed for the individual system components.
Next window button
1
Previous window button
2
Remaining run time of high-pressure pump
3
Remaining run time of dosing pump 1
4
Remaining run time of dosing pump 2
5
Remaining run time of RO pump (option)
6
Remaining run time of ultra-fine filter (WSO)
1
22
Menu System Information
In the System Information menu, system data, settings
of the control and operations data of the control are dis-
played.
Next window button
1
Previous window button
2
Software version
3
Material number of the system
4
Serial number of the system
5
Serial number of the control
6
IP settings of the control
1
Run time of the control in hours
2
Initial startup date
3
Last service
4
Current number of faults in the fault memory / last
1
reset of the fault memory
Menu Fault History
In the Fault History menu, the error messages since the
last deletion of the fault memory are displayed.
Delete fault memory button
1
Error description
2
Time of the error message
3
Error number
4
English
Delete the fault memory
1
Are you sure you want to delete the fault memory?
2
No
3
Yes
4
Menu Event History
The Event History menu is structured in the same way
as the Fault History menu.
Frost protection (option)
The frost protection device consists of a hot air blower and an-
tifreezing circulation or frost protection with lost water.
Note: The presence of a frost protection system en-
sures the following properties:
● Restricted washing operation at temperatures be-
low – 5 °C. In restricted washing operation the
washing brush must be regularly checked for icing.
Brush washing with an iced washing brush can
damage the vehicle. If the washing brush is iced up,
the washing brush must be disabled or, in the case
of the 1-tool version, the combination spray lance
must be replaced with a high-pressure spray lance.
Please contact your Customer Service responsible
if washing operation is to be extended to lower tem-
peratures. At temperatures below –15 °C, washing
makes no sense because an ice coating forms on
the vehicle. This ice coating can even impair the
function of important vehicle components. For this
reason, you must lock the system at temperatures
less than –15 °C.
● Frost protection of the system down to –20 °C. At
temperatures less than–20 °C the "Frost shutdown"
procedure is to be performed.
WARNING
Frost protection water running onto the washing sta-
tion can lead to the formation of black ice under frosty
conditions.
Insert the high-pressure gun into the brush chute after use.
WARNING
Black ice on the washing station presents an in-
creased danger of accidents.
Lock the washing station if there is a danger of black ice.
Prerequisites for frost protection
● An uninterruptible power supply and water supply
must be ensured. The water supply must be protect-
ed against frost.
● Technically correct erection and installation of the
system.
● The hot air blower is set correctly.
● All maintenance measures described in the "Mainte-
nance and care" chapter have been performed.
● All cleaning tools are placed back in the tool holders.
● The high-pressure gun with frost protection bore be-
longing to the system is installed.
● The hose line from the system to the cleaning tool has
not been extended or replaced with a longer hose.
● The temperatures stated above relate to the instal-
lation site. Temperatures stated in weather forecasts
are secondary.
Hot air blower
The hot air blower heats the interior of the system to
provide frost protection.
1. Turn the performance controller to level "I".