Descargar Imprimir esta página

Graco FT500 Funcionamiento página 49

Pulverizadores eléctricos sin aire

Publicidad

Digital Display Messages
No display does not mean sprayer is not pressurized. Relieve Pressure before repair, page 16.
DISPLAY
SPRAYER OPERATION
No Display
Sprayer stops. Power is not applied.
Sprayer may be pressurized.
Sprayer is pressurized. Power is applied
(pressure varies with tip size and pressure
psi
control setting).
bar
MPa
ti6315a
Sprayer may continue to run.
Power is applied.
ti6316a
Sprayer stops. Power is applied.
ti6317a
Sprayer stops. Power is applied.
Sprayer does not start or stops.
Power is applied.
ti6318a
Sprayer stops. Power is applied.
- - - - -
Power is applied.
Sprayer stops. Power is applied.
313433D
INDICATION
Loss of power
Normal operation
Pressure greater than
4500 psi (310 bar, 31 MPa)
or pressure transducer faulty
Pressure transducer faulty,
bad connection, or broken
wire
Line voltage too high
Motor fault
Motor is too hot
Pressure less than 200 psi
(14 bar, 1.4 MPa)
Empty paint pail.
Loss of pressure.
Repair / Réparation / Reparación
ACTION
Check power source. Relieve
pressure before repair or
disassembly.
Spray
Replace pressure control board
or pressure transducer
Check transducer connection. Open
drain valve. Substitute new transducer
in sprayer. If sprayer runs, replace
transducer.
Check for voltage supply problem.
Check for locked rotor, shorted wiring
or disconnected motor. Repair or
replace failed parts.
Allow sprayer to cool. If sprayer runs
correctly when cool, check motor fan
function and air flow. Keep sprayer in
cool location. If sprayer does not run
when cool and continues to blink
6 times, replace motor.
Increase pressure if desired.
Drain valve may be open.
Refill paint pail. Check for leaks or
clogged pump inlet. Repeat Start-up
procedure.
49