INSTALL THE SQUEEGEE
1
See Figure 2-6. Slide the Squeegee Assembly (11) onto the squeegee mount bracket and tighten the Squeegee Removal Knobs (38).
2
Connect the Recovery Hose (34) to the squeegee inlet.
Lower the squeegee, move the machine ahead slightly and adjust the squeegee tilt and height using the Squeegee Tilt Adjust Knob (35) and
3
Squeegee Height Wheel (AC) so that the rear squeegee blade touches the floor evenly across its entire width and is bent over slightly as
shown in the squeegee cross section.
FIGURE 2-6
AC
FILL THE SOLUTION TANK
Open the Solution Tank Fill Cap (40) then fill the tank with a maximum of 26 US gallons (100 liters) of cleaning solution.
The machine is equipped with EcoFlex - a detergent dispensing system. When using this system the solution tank should be filled with plain water.
The machine can also be used conventionally with detergent mixed with water in the tank. Always follow the dilution instructions on the detergent
container label. The solution should be a mixture of water and the proper cleaning detergent for the job.
CAUTION!
Use only low-foaming, non-flammable liquid detergents intended for automatic scrubber machine applications. Water temperature
should not exceed 130 degrees Fahrenheit (55 degrees Celsius).
NOTE: When refilling the solution tank always empty the recovery tank using Recovery Tank Drain Hose (36).