Getting started
Administrator Mode
With Administrator Mode, the administrator can check cycle parameters, adjust cycle parameters, and manage coin
pricing.
Two methods to enter Administrator Mode:
Method 1
Hold down Cold and Heavy Soil at the same time for 10 seconds and listen for the chime sound as you enter
Administrator Mode. While entering the Administrator Mode a 4 digit password is required to enter next step. The
display will show "0000" at the beginning. Each press of the Cold button will increase the first digit from "0" to "9" and
repeating. Each press of the Warm button will increase the second digit from "0" to "9" and repeating. Each press of
the Hot button will increase the third digit from "0" to "9" and repeating. Each press of the Delicate button will increase
the fourth digit from "0" to "9" and repeating. Once the 4 digits are ready, press the Start/Pause button to confirm. The
default password is 1234.
Method 2
Single press of the Reset button on the board will enter into Administrator Mode. This will not require a pin. The location
of the Reset button is shown on page 13.
Exit the Administrator Mode by pressing the Reset button again, pressing and holding Cold and Heavy Soil at the
same time for 10 seconds.
View and Edit Administrator Parameters in Administrator Mode:
After entering Administrator Mode, register address "Ad" will flash in the display and register "00" will be the first accessible
register. LEDs above push buttons will blink when a button is available for activating a function or changing a value.
How to Navigate Parameter Registers:
The Heavy Soil (step down) and Extra Rinse (step up) buttons will be used to navigate the different register
addresses. Pressing and holding either of these buttons will result in an increasingly-faster decrement or increment
of the register address (without beep for repeated steps). Register numbers that are not assigned a function may be
skipped over when navigating.
How to View and Edit a Parameter:
When a register address is selected, press Start/Pause button, the display will show the register contents, and the
Cold, Warm, Hot and Delicate buttons will be used to set the value of the 4 digit parameters. After setup of the
parameters, press the Start/Pause button to save the new value and return to Register Navigation Mode. For values,
the button corresponding to the display digit where the value is shown will toggle the value 0 / 1 / 0 / 1 etc.
If the register value is "read only" the Cold, Warm, Hot and Delicate lights will be off and presses of the buttons will
emit an invalid sound (ding-ding). If register contents are editable, LEDs above the buttons that can be used to edit
the register will flash.
Machine Usage Registers
Registers 00-07 track the number of operating hours the unit has run for a given cycle or combination of cycles.
Register 09 will count amount earned from 0-99.75. Once the unit collects $100, register 08 will be incremented by 1
(where 1 represents $100).
00
Total operating time for Cold cycle. From 0000-F999
01
Total operating time for Warm cycle. From 0000-F999
02
Total operating time for Hot cycle. From 0000-F999
03
Total operating time for Delicate cycle. From 0000-F999
04
Total operating time for Heavy Soil cycle. From 0000-F999
05
Total operating time for Extra Rinse cycle. From 0000-F999
06
Total operating time for Heavy Soil + Extra Rinse. From 0000-F999.
07
Total operating time for Cold + Warm + Hot + Delicate. From 0000-F999.
08
Total amount earned from Coin Pay — hundreds. From $0000-$9999.
09
Total amount earned from Coin Pay. From $00.00-$99.99.
10
49-3000277 Rev 0