171...
3
Approval
The following types are approved according to ANSI/UL 508 and CSA
C22.2#14:
171262AFA, 171271, 171271A0D, 171271A0E,
171271AA, 171271AM, 171271AY, 171271AZ,
171V62, 171V62A0D, 171V62AY
171262V, 171271V, 171271VZ
3079760
CONFORMS TO
ANSI/UL 508
CERTIFIED TO
CAN/CSA C22.2#14
4
Safety instructions
- Ensure that the safety sensors are only mounted and put into
operation by specially-trained and authorised personnel.
- Only install and put the device into operation once you have
read and understood the operating instructions and are familiar
with the applicable regulations on occupational safety and
accident prevention.
- The safety sensor may only be activated by a correctly mounted
actuator on the safety device. Actuation by means of a spare ac-
tuator that is not mounted to the safety device is prohibited.
- The safety sensors may only be operated in a perfect
functioning condition.
- Ensure that the safety sensors are exclusively used to protect
against risks.
- Ensure that all of the valid safety regulations for the respective
machine are complied with.
- Ensure that all of the valid laws and directives are complied with.
- Connecting safety sensors in series can, under certain
circumstances, reduce their performance level according to EN
ISO 13849-1 standards due to a lower detection of errors.
- There are no known residual risks, if all of the information
contained in these operating instructions is complied with.
5
Warning against misuse
- In case of incorrect or unintended use or manipulation, the use
of the safety sensors does not exclude risks to persons or
damage to machine or system components. Please also
observe the relevant information stipulated in EN ISO 14119.
- Please ensure that when using safety control units that have not
been supplied by elobau, no current or voltage peaks which are
higher than the specified electrical data of the safety sensor are
generated by these devices. Current or voltage peaks are pro-
duced, for example, by capacitive or inductive loads.
- The safety sensor is not short-circuit proof.
- An exceeding of the electrical data of the safety sensor (e.g. in
the event of incorrect wiring or short-circuits) may cause irrepa-
rable damage to the sensor.
- The safety sensor may only be activated in the approved control
options (see 'Technical specifications').
Non-compliance with this information may result in reduced ser-
vice life of the safety sensor.
6
Exclusion of liability
No liability shall be accepted for any damage or operational faults caused by
a failure to observe these operating instructions. All further liability of the
manufacturer is excluded in the case of damage caused by the use of
replacement and accessory parts that have not been authorized by the
manufacturer.
No unauthorized repairs, conversions or modifications are permitted for
reasons of safety and the manufacturer shall not be liable for any resulting
damage.
Art.-Nr./Art. No./Réf./N° art/N° art.: 9010009B01M
7
A coded magnetic safety sensor with a non-contact activation through a coded
actuator.
Type 4; low coding level according to EN ISO 14119.
An elobau safety control unit or similar safety processing unit / safety controller
analyses the switching state of the safety sensor.
The safety sensors are suitable for the following elobau safety evaluation
units:
Safety sensor
( 1 )
( 2 )
( 3 )
( 4 )
( 5 )
( 6 )
8
See technical specifications beginning on page 14.
Version/Version/Version/Versione/Versión: 2.0
Function
(6)
171V62VY,
171V62VY01,
171V62A0D,
171V62AY, 171V62,
171V62W, 171V62V,
171562
171271AY,
171271A0D, 171271,
171271A10,
171271V, 171271W,
171271VY01,
171271VY03,
17127113,
171271V05,
171271AY01,
171271VY02, 171571
171271A0E,
171271AM,
171271AZ,
171271AA,
171271VZ,
171571AA
171262V, 171262W,
171262AFA
Up to cat.3/PLd (EN ISO 13849-1)
Up to cat.4/PLe (EN ISO 13849-1)
Up to SIL2 (IEC/EN 61508)
Up to SIL3 (IEC/EN 61508)
Deactivate test pulses, cross-circuit detection by plausibility (cross
comparison) of NC/NO contacts at the inputs. Activation simultaneity
recommended
For sensor variants not listed here, the achievable safety level is
identical to that listed above, according to the respective contact
variant of the sensor (only working open contacts)
Technical specifications
Datum/Date/Date/Data/Fecha: 29.07.2022
Safety evaluation unit
(1)
(2)
(1)
(2)
-
(3)
(4)
(3)
(4)
(2)
(1)
(1)
(2)
-
(4)
(3)
(3)
(4)
(2)
(1)
(1)
(2)
-
(4)
(3)
(3)
(4)
On request
(2)
(4)
(2)
(4)
(2)
(4)
(5)
4/23