Technical Information
Table 7
I/O Type
Analog Output
Output Relay
+24 Vdc
Connection of Input Remote
To activate the inputs remote (CH on/off) connect the pins as following:
Figure 51 Input
Agilent IPCMini Ion Pump Controller User Manual
ON
OFF
+24V
10 KΩ
Input pin
A
Digital GND
Controller
I/O Ratings
Max Load
Note
1mA
Range 0-10V
24V , 100mA max
24V +/- 10% - 80mA max
Customer
device's