Descargar Imprimir esta página

Selco Genesis 200 AC-DC/TLH Instrucciones De Uso página 24

Ocultar thumbs Ver también para Genesis 200 AC-DC/TLH:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
4.6 Technical characteristics
Supply voltage
(50/60Hz)
Max. absorbed power
in TIG (x=40%)
Max. absorbed current
in TIG (x=40%)
Absorbed current
in TIG (x=100%)
Max. absorbed power
in MMA (x=40%)
Max. absorbed current
in MMA (x=40%)
Absorbed current
in MMA (x=100%)
Power factor
Cosj
Welding current in TIG
(x=40%)
(x=60%)
(x=100%)
Current in MMA
(x=35%)
(x=60%)
(x=100%)
Adjustment range in
TIG (MMA)
Open-circuit voltage
Protection rating
Insulation class
Construction standards
Dimensions (lxdxh)
Weight
Data at 40°C ambient temperature.
Supply voltage (50/60 Hz)
Nominal input current
Capacity of reservoir
Cooling power
Protection rating
Dimensions (lxdxh)
Weight with liquid
5.0 TRANSPORT - UNLOADING
Never underestimate the weight of the equipment, (see
technical specifications)
Never make the cargo pass or leave it suspended over
people or things.
Neither let the equipment or the single unit fall, nor
put it down with force.
Once it has been removed from the packing, the
power source is supplied with an extendible belt which
can be used to move it in the hand or on the shoulder.
24
G 200 TLH
G 200 AC-DC
1x230V ± 15%
1x230V ± 15%
4.9kW
5.3kW
21.8 A
23.4 A
12.9 A
14.2 A
6.0 kW
6.6 kW
26.7 A
28.8 A
17.9 A
18.7 A
0.99
0.99
200 A
200 A
170 A
170 A
140 A
140 A
180 A
180 A
150 A
150 A
130 A
130 A
6-200 (180 A)
6-200 (180 A)
53.7 V
53.7 V
IP23C
IP23C
H
EN60974-1
EN60974-1
EN50199
EN50199
179x430x293 mm
179x430x293 mm
16 Kg.
16 Kg.
WU15
1x230 V ± 15%
0.8 A
900 W
IP23C
179x430x160 mm
9.5 Kg.
G 202 TLH
1x230V ± 15%
(1x115V ± 15%)
4.9kW (3.86 kW)
21.8 A (33.9 A)
12.9 A (22.2 A)
6.0 kW (4.51 kW)
26.7 A (39.7 A)
17.9 A (24.4 A)
0.99
0.99
0.99
0.99
200 A (160 A)
170 A (130 A)
140 A (120 A)
180 A (130 A)
150 A (110 A)
130 A (90 A)
6-200/6-180 A
(6-160/6-130 A)
53.7 V
IP23C
H
H
EN60974-1
EN50199
179x430x293 mm
16 Kg.
1.7 l
6.0 INSTALLATION
Choose an adequate installation area by following
the criteria provided in Section "1.0 SAFETY" and
"2.0 ELECTROMAGNETIC COMPATIBILITY (EMC)".
Do not position the power source and the equip-
ment on surfaces with inclination exceeding 10°
with respect to the horizontal plane.
Protect the installation from heavy rain and sun.
Do not use the power source to thaw pipes.
G 202 AC-DC
1x230V ± 15%
(1x115V ± 15%)
5.3kW (4.15 kW)
23.4 A (36.6 A)
14.2 A (23.9 A)
6.6 kW (4.76 kW)
28.8 A (41.2 A)
18.7 A (25.6 A)
0.99
0.99
200 A (160 A)
170 A (130 A)
140 A (120 A)
180 A (130 A)
150 A (110 A)
130 A (90 A)
6-200/6-180 A
(6-160/6-130 A)
53.7 V
IP23C
H
EN60974-1
EN50199
179x430x293 mm
16 Kg.

Publicidad

loading

Este manual también es adecuado para:

Genesis 202 ac-dc/tlh