ATTENTION: If the values of the programming menu
A0 to A4 are changed, the load switch-off no longer
DA
provides any protection! Teach the door operator in again
before re-commissioning. For this carry out Teaching in the
NO
door operator (Chapter 15) .
FI
Menu
Function, setting range, unit
A0 Length SOFT RUN OPEN in 7cm
NL
000..009
A1 Length SOFT RUN CLOSE in 7cm
IT
000..009
A2 Soft running speed (CLOSE) mm/s
000= 50...009= 140
HU
A3 Backjump, OFF= 000 ON= 001
A4 Change in direction, OFF= 000 ON= 001
RU
Setting (with +/-) only possible if EMERGENCY
STOP plug (1, green) is unplugged.
PL
A5 Added load OPEN
A6 Added load CLOSE
A7 Door type: Overhead sectional door/one-piece
SI
door = 000
Side sectional door* = 001
Side sectional door with soft start = 002
CZ
* Obstruction release also in OPEN direction
If A7 was changed, perform a reset
SK
and then teach in the door operator again.
(Chapter 15).
A8 Warning time (OPEN/CLOSE) 001=2sec...
GR
008=16sec
A9 Accessory card
ES
000= ZKMagicS
001= ZKMagic
b0 Relay 1 (with ZKMagic accessory card)
PT
000= no function
001= E-lock
002= warning light*
BG
003= photo cell test* (interruption transmitter
voltage)
HR
004= status display*: Door in end position OPEN
005= status display*: Door in end position
CLOSED
RO
006= green light*
007= red light*
* if A9= 001
UAE
18 / 240
Factory setting
1)
000..030
1)
000..030
(Chapter 19)
b1 Relay 2 (with ZKMagic accessory card)
000= no function
001= E-lock*
002= warning light*
003= photo cell test* (interruption transmitter
voltage)
004= status display*: Door in end position OPEN
005= status display*: Door in end position
CLOSED
006= green light*
007= red light*
* if A9= 001
b2 Closing edge protection, for accessory card
ZKMagic and if A9= 001
000= OFF
b3 Empty run detection 000= OFF 001= ON
b4 Automatic closing
000= OFF
001.0.010 keep-open time secs.*
(001 = 5secs... 010 = 50secs)
011..040 keep-open time min*
(011=1min... 040=30min) * plus warning time
002
* only active if door was fully opened
b6 Maintenance interval
004
000= OFF
001..009 (1,000 door movements)
005
Example: 005 = 5,000 door movements
The operator lighting flashes after every door
001
movement when the maintenance interval has run
out. A misadjustment resets the counter of the
000
maintenance interval.
b7 Version number
Each of the digit positions (0-7)
003
is displayed in turn.
003
The example shows:
000
Version: 04 Date: 20.05.10
Select the position with the pushbuttons
b8 Service mode
000= control panel free, menu items adjustable
001= control panel locked, menu items not
adjustable
002= data output (accessory card)
Setting only possible if EMERGENCY STOP plug
000
(1, green) and photo cell (2, yellow) are
unplugged.
000
b9 Run counter (not adjustable)
Each of the digit positions (0-5)
is displayed one after another.
The example shows the value
000
8,000
Select the position with the pushbuttons
C0 Test mode for Magic-Door-Control (option)
Radio signal, maximum 15 seconds:
000= no signal
001= end position OPEN
002= end position CLOSED
003= run open
004= run close
005= standstill underway
007= error
008= obstruction
IP2286 11/2021
001= OSE
002= 8k2
1)
*, secs. and min.
04200510
01234567
and
008000
012345
and
Magic 1000-3
000
000
001
000
000
.
000
.
000

Publicidad

loading

Productos relacionados para Normstahl Magic 1000-3