For Fronius Galvo/Fronius Symo/Fronius Primo only and when linking multiple invert-
2
ers in Fronius Solar Net:
Set the Fronius Solar Net master/slave switch on the Fronius Datamanager 2.0 plug-
in card as required
-
One inverter with Fronius Datamanager 2.0 = master
-
All other inverters with Fronius Datamanager 2.0 = slave (the LEDs on the Fro-
nius Datamanager 2.0 plug-in cards are off)
Switch the device to service mode
3
Inverter with Fronius Datamanager 2.0 plug-in card:
-
Switch the IP switch on the Fronius Datamanager 2.0 plug-in card to position A
or
-
Activate the WIFI Access Point via the Setup menu of the inverter
(the performance of this function depends on the inverter software)
S t a n d b y
W i F i A c c e s s P o i n t
D A T C O M
U S B
C l o c k
Fronius Datamanager Box 2.0:
-
Switch the IP switch on the Fronius Datamanager Box 2.0 to position A
The inverter/Fronius Datamanager Box 2.0 establishes the WLAN Access Point. The
WLAN Access Point stays open for one hour.
Download Fronius Solar.web App
4
Run Fronius Solar.web App
5
The start page of the Commissioning Wizard appears.