Class 3 Status Codes - Fronius Primo 3.8-1 208-240 Manual De Instrucciones

Inversores para instalaciones fotovoltaicas acopladas a la red
Ocultar thumbs Ver también para Primo 3.8-1 208-240:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Code
Description
241
Arc detected
242
Arc detected
245
Arc detector self test failed
Arc detector current sensor de-
247
fective
249
Arc detector defective
Class 3 Status
Class 3 includes status codes that may appear during grid power feed operation and do
Codes
not cause permanent interruption of the grid power feed operation.
After automatic disconnection from the grid and waiting for its conditions to return to those
stipulated, your inverter will try to resume grid power feed operation.
Code
Description
301
Over-current (AC)
302
Over-current (DC)
Power stage set over tempera-
303
ture
304
Interior temperature too high
LOW PV POWER
Intermediate circuit voltage
306
has dropped below permissible
threshold value for grid power
feed operation.
LOW PV VOLTAGE
DC input voltage has dropped
307
below permissible threshold
value for grid power feed oper-
ation.
44
Details
The status code 241 is dis-
played directly after 240; the
inverter disconnects from the
grid for safety reasons.
Status code 242 is displayed
after resetting status code 241.
The inverter disconnects from
the grid.
The inverter disconnects from
the grid.
Details
Brief interruption of grid power
feed operation due to overcur-
rent in the inverter.
The inverter returns to the
startup phase.
Brief interruption of grid power
feed operation due to over
temperature.
The inverter returns to the
startup phase.
Brief interruption of grid power
feed operation.
The inverter returns to the
Startup phase.
Rectification
If an arc has been detected,
check the entire affected PV
system for damage before re-
setting the inverter.
Reset status code by pressing
the "Enter" key.
Reset the status code by
pressing the "Enter" key.
The inverter resumes grid
power feed operation.
If the status code keeps recur-
ring, contact your system in-
staller.
Reset AC.
The test is repeated.
If the status code persists:
contact a Fronius-trained ser-
vice technician.
If status code persists: contact
a Fronius-trained service tech-
nician.
Rectification
Error is automatically rectified;
if status code persists: contact
a Fronius-trained service tech-
nician.
If required, clean cool air vents
and cooling elements with
compressed air.
The fault is rectified automati-
cally.
If this status code keeps recur-
ring, contact your system in-
staller.
The fault is rectified automati-
cally.
If this status code keeps recur-
ring with sufficient solar irradi-
ance, contact your system
installer.