Descargar Imprimir esta página

Motorola IMPRES 2 Guia Del Usuario página 11

Ocultar thumbs Ver también para IMPRES 2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 144
feature prevents battery over-charging and minimizes the loss of cycle
life. This is especially important when charging Nickel batteries.
Automatic IMPRES 2 or IMPRES Battery Calibration /
Reconditioning
The IMPRES 2 charger automatically assesses the condition of an
IMPRES 2 or IMPRES battery. Based on this condition, the charger
automatically calibrates / reconditions the battery. Interruption of either
the discharge phase or the full charge phase delays Calibration until
the next charging opportunity.
Use Charger Setup Mode to enable or disable Calibration/
Reconditioning. When disabled and the IMPRES 2 or IMPRES battery
requires Calibration/Reconditioning, the LED indicates Alternating
Amber/Green at battery insertion and after the battery is charged.
Note: The IMPRES 2 or IMPRES battery must be outside the charger
pocket for more than 30 minutes for automatic Calibration/
Reconditioning.
IMPRES Battery with Self Calibration and Recondition
ATTENTION: IMPRES 2 batteries that has this icon on the
battery label do not require periodic calibration and
reconditioning when docked into this IMPRES 2 charger
(with software version V2.05 or newer).
Note: Ensure that your charger is always updated with the latest
firmware. The MSI Charger Reprogrammer application package
can be downloaded from Motorola Online (MOL) or Motorola
Solutions website.
Updating Firmware
Note: Applies to all IMPRES Gen 1 and Gen 2 devices or chargers;
which includes Charger Interface Unit (CIU), Battery Data
Reader (BDR), Single-Unit Charger (SUC), Dual-Unit Charger
(DUC), and Multi-Unit Charger (MUC).
Remove all inserted batteries from target device or charger before
upgrading an IMPRES device or charger to a newer version.
8

Publicidad

loading