Manually Initiating Calibration/Reconditioning
ATTENTION: Manual calibration or reconditioning does not
apply to IMPRES or IMPRES 2 batteries that has this icon.
Though Calibration/Reconditioning is automatic, there may be
situations in which manual initiation is desired. For example, the
charger may be indicating Alternating Amber/Green for the IMPRES
2 or IMPRES battery, because calibration is disabled in the charger. If
within 30 minutes that battery is moved to a charger that has
calibration enabled, the last charging state resumes, preventing
automatic start of Calibration/Reconditioning.
To manually initiate Calibration/Reconditioning, remove the IMPRES 2
or IMPRES battery from the charger for more than 2.5 minutes. Then,
perform the following steps:
1. Insert the battery into the charger pocket.
2. Within 2.5 minutes, remove the battery from the charger pocket.
3. Within 5 seconds, reinsert the battery into the charger pocket.
Calibration/Reconditioning starts immediately, typically beginning with
Battery Discharge (Steady Amber). Calibration/Reconditioning is
complete only after full charge (Steady Green).