ERROR
FAULT
Mains
0
E1 →
8
failure
Communication
10
E1 →
error
Initialization er-
11
E1 →
ror
Mains
13
E1 →
nection error
Mains
14
E1 →
error
Empty pan pro-
15
E1 →
tection
FAULT MESSAGES FROM THE DIGITAL CONTROLS (E2)
ERROR
02
Potentiometer integrity
E2 →
Double-Sided
03
E2 →
lost
LIN
Bus
05
E2 →
open
06
LIN Bus conflict
E2 →
- Interrupted iring
10
E2 →
- Incorrect ID
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
CAUSE
-
Interruption
phase
network phase or insuffi-
cient or poor network qua-
lity
No connection between
keyboard and generator
- Check potentiometer ID
- Error during hardware
initialization
- RJ45 CAN-Bus termi-
nation disconnected or
damaged
con-
Mains voltage is too high or
too low
adaptor
Mains voltage is too high or
too low
- Power supply error
- Empty pan
- Damaged temperature
sensor
FAULT
Damaged potentiomete
control
One of Double-Sided
nodes damaged
connection
No communication de-
tected
Conflict ID
-
between keyboard and
generator
- The digital control has
an incorrect ID
- 19 -
MAINTENANCE
INTERVENTION
of
the
- Call technical authorized ser-
vice
- Call technical authorized ser-
vice
- Call technical authorized ser-
vice
- Call technical authorized ser-
vice
- Call technical authorized ser-
vice
- Turn the knob to "zero", wait 5
minutes and turn on again
- Remove pan, switch off and
wait for the hob to cool down
- The sensor must be replaced
CAUSE
Connection
fault
INTERVENTION
- Call technical authori-
zed service
8.