Feature Identification
C
ON/OFF Switch: When you set the switch to the ON position,
the Inverter provides AC power by converting DC power from the
connected 12V battery system. Set the switch to the OFF position
to shut down the Inverter and conserve the battery's charge when
you are not using connected equipment. Also set the switch to
the OFF position to reset the Inverter if it has shut down due to
overload or other critical events. See the Operation section for
more information.
D
LED Status Indicators*: When the switch is set to the ON
position, the LED system will illuminate green during normal, low
voltage alarm and output short circuit conditions. If there is an
overload, over-temperature, or if a high/low DC voltage shutdown
condition occurs, the LED system will illuminate red.
*PINV750 has separate green and red LED indicators for monitoring the
below status conditions. See the below chart for exact LED and alarm
status based on operating condition:
E
Temperature/Load-Controlled Cooling Fan: This fan regulates
the internal temperature of the inverter and prolongs service
life. It will only come on if the temperature or load demand goes
beyond the set thresholds.
F
DC Power Terminals: These positive and negative terminals
connect to the battery via the included or user-supplied cabling.
See Battery Connection for instructions.
18-06-149-93385F.indb 7
LED
Normal
Low
Operation
Voltage
Voltage
Status
(12V)
alarm
Green LED
ON
ON
Status
Red LED
OFF
OFF
Status
Alarm
OFF
ON
Low
High
Voltage
Voltage
Shutdown
Shutdown
Temperature
OFF
OFF
ON
ON
ON
ON
7
Output
Over-
Output
Short
Overload
Circuit
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF