The following example applies to a pump or motor
in an application where a pressure sensor gives a
feedback to the pump or motor. The sensor has
been set manually, and the pump or motor does
not automatically register a connected sensor.
Light fields 5 and 6 are activated, indicating a
desired setpoint of 72.5 psi (5 bar) with a sensor
measuring range from 0 to 145 psi (0 to 10 bar).
The setting range is equal to the sensor
measuring range.
[bar] [psi]
10
145
5
72.5
0
0
7.9.3 Resetting alarms and warnings in
products with a standard operating panel
•
You can reset a fault indication in one of the
following ways:
-
Briefly press the Up or Down button.
This is not possible if the buttons have
been locked.
This does not change the setting of the
motor.
-
Switch off the power supply until the
indicator lights are off.
-
Switch the external start and stop input off,
and then on again.
-
Use Grundfos GO Remote.
-
Use the digital input if you have set it to
Alarm resetting.
24
7.10 Setting by means of Grundfos GO
Remote
7.10.1 Grundfos GO Remote
The product is designed for wireless radio or
infrared communication with Grundfos GO
Remote.
Grundfos GO Remote enables you to set
functions and gives you access to status
overviews, technical product information, and
current operating parameters.
Use Grundfos GO Remote together with this
mobile interface:
•
Grundfos MI 301.
Pos. Description
Grundfos MI 301:
Separate module enabling radio or infra-
1
red communication. Use the module to-
gether with an Android or iOS-based
smart device via a Bluetooth connection.
7.10.2 Communication
When Grundfos GO Remote initiates
communication with the product, the indicator light
in the center of Grundfos Eye flashes green.
On products fitted with an advanced operating
panel, the display indicates that a wireless device
is trying to connect to the product. Press OK on
the operating panel to connect the product with
Grundfos GO Remote, or press the Home button
to reject connection.
1
+