Malfunctions and solutions
8.4
Problem
NO MACHINE POWER
NO WATER IN THE HEATING UNIT
TOO MUCH WATER IN THE HEATING
UNIT
STEAM NOZZLES DO NOT RELEASE
STEAM
STEAM NOZZLES RELEASE WATER OR
STEAM MIXED WITH WATER
NO BEVERAGES ARE DISPENSED
WATER LEAKS FROM THE MACHINE
COFFEE IS TOO HOT OR TOO COLD
THE COFFEE GROUNDS ARE WET
THE GAUGE INDICATES A
NON-CONFORMING PRESSURE
COFFEE IS ONLY DISPENSING VIA THE
MANUAL BUTTON
THE ELECTRONIC SYSTEM HAS
SHUTDOWN
WATER IS LEAKING FROM THE PUMP Pump fault.
THE MOTOR STOPS SUDDENLY OR THE
THERMAL PROTECTOR IS TRIGGERED
BY A POWER OVERLOAD
THE PUMP IS WORKING BELOW THE
NOMINAL FLOW RATE
THE PUMP IS NOISY
Problems highlighted in grey require the machine to be switched
off and one of the Manufacturer's Qualified Technicians to be
called out.
USER Manual
LB4722-LB4723-LB4724 LB4733-LB4734
Cause
The machine is switched off.
The water mains tap is shut off.
Electrical system or hydraulic system fault.
The nozzle sprayer is clogged.
The machine is switched off.
Electrical system or hydraulic system fault.
The water mains tap is shut off.
The tray is not draining.
The drain pipe is broken, has detached, or the water
flow is obstructed.
Electrical system or hydraulic system fault.
The dispensing group is too cold.
Hydraulic system fault.
Electronic system fault.
Electrical system or hydraulic system fault.
Pump fault.
Pump fault.
Pump fault.
Action
Turn on the machine.
Open the water mains tap.
Turn off the machine and call out the Technical
Support.
Clean the steam nozzle sprayer.
Turn on the machine.
Turn off the machine and call out the Technical
Support.
Open the water mains tap.
Check the sewer drain.
Check and restore the drain pipe connection to
the tray.
Turn off the machine and call out the Technical
Support.
Wait for the group to fully heat up.
Turn off the machine and call out the Technical
Support.
Turn off the machine and call out the Technical
Support.
Turn off the machine and call out the Technical
Support.
Turn off the machine and call out the Technical
Support.
Turn off the machine and call out the Technical
Support.
Turn off the machine and call out the Technical
Support.
Turn off the machine and call out the Technical
Support.
53
176
of