Descargar Imprimir esta página

STAMOS S-WIGMA200M Manual De Instrucciones página 26

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
Long rear cap
1 -
Short rear cap
2 -
Collet
3 -
Torch holder
4 -
Collet in housing
5 -
Ceramic nozzle
6 -
7. Connecting the wires
CAUTION! Connecting the cables to the device must be done with the power supply disconnected
and the device turned off.
Checking the tightness of gas connections
Before first use and then at regular intervals, it is recommended to check for gas leaks. The
procedure should be carried out as follows:
1) Connect the regulator and gas line assembly and tighten all connections and clamps.
2) Slowly open the cylinder valve.
3) Set the flow rate on the controller to approximately 8-10 l/min.
4) Close the cylinder valve and watch the pressure gauge needle on the regulator. If the needle
drops towards zero, it means there is a gas leak. Occasionally, the gas leakage can be slow.
To identify it, leave the gas pressure in the regulator and the line for a long time (about 15
minutes).
5) In the event of a gas leak, check all connections and terminals for leaks. Brushing or spraying
with soapy water will cause bubbles to appear at the location of the leak.
6) Tighten clamps or couplings to eliminate gas leakage.
IMPORTANT! - It is recommended to check for gas leakage before starting the machine. It is
recommended to close the cylinder valve when the machine is not in use.