9. Programming the Receiver Operating Frequency
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY
9.1
Turn the Wall Control ON/OFF Switch to the "OFF"
position.
Restore electricity to the Ceiling Fan Branch Circuit at
the Circuit Breaker or Fuse Box
Flip the Wall Control's ON/OFF Switch to "ON" position.
Within one minute of flipping the Switch to "ON", push
and hold the FAN OFF Button (
to set the Code in the Receiver. The Ceiling Fan lights
(if installed) will blink to indicate the Wall Control Code
has been paired with the Receiver.
All manuals and user guides at all-guides.com
9.2
If programming is unsuccessful, retry the previous
instructions after cycling the Wall Control ON/OFF
Switch to restart the 1 minute programming time period.
9.3
If still unsuccessful, shut off the Electricity at the Fuse
Box or Breaker Panel and change the Wall Control
Frequency (page 18). After changing the Frequency
Settings, repeat 9.1 within one minute of restoring the
Electricity.
) for 3 to 5 seconds
23
Please contact 1-800-654-3545 for further assistance