Using two people to lift, rest the hood on the screws in
2.
the wood bracket. Use the keyholes (F). Make sure the
wood bracket fits into the recess on the back of the
hood.
Tighten the screws in the keyholes. Check hood
3.
levelness and adjust if necessary.
From inside the hood, drive ⅝" (16 mm) screws through
4.
holes in hood into wood support bracket (J).
Connect additional ducting.
5.
5.5 Cabinet installation
The hood can be installed under a cabinet by supporting
the hood from the top.
Note: The cabinet must be structurally joined to the wall
studs to support the weight of the hood. Check the
structural integrity of the cabinet and wall before
proceeding.
16
The figure shows the (4) screw holes (K) used for
1.
mounting the hood to the bottom of the cabinet. Make
sure both knockouts have been removed.
Hood size
30" (762 mm)
36" (914 mm)
42" (1067 mm)
48" (1219 mm)
54" (1372 mm)
60" (1524 mm)
In the base of the cabinet, drill ⅛" (3 mm) tap holes
2.
spaced as indicated by dimension A.
Screw in four (4) 1" (25 mm) screws (provided) leaving
3.
¼" (6 mm) exposed to hang the hood on.
For vertical discharge, create clearance holes for
4.
passage of the transition and conduit as shown in
→  "Cutout for vertical discharge", Page 14 .
For horizontal discharge, follow the instructions form
5.
horizontal discharge transition for the geometry of the
cutout required for clearance of the transition.
→  "Cutout for horizontal discharge", Page 14
Hang the hood from screws and tighten securely.
6.
From inside of hood, insert the screws supplied. Drill
7.
through holes, use the ⅝" (16 mm) screws supplied, (1)
on each side and (4) along the front, into bottom of the
cabinet. See screw holes labeled "L" in figure.
5.6 Blower motor installation
CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the Ventilation
Planning Guide.
Note: Cutting the plug of the blower will void the warranty
or eligibility for return or exchange.
A
29" (737 mm)
35" (889 mm)
41" (1041 mm)
47" (1194 mm)
53" (1346 mm)
59" (1499 mm)