en-us Installation requirements and clearances
3.2 Clearances
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
X
Electrical zone
*Follow cooking appliance manufacturer's
recommendations.
3.3 Hood width
The hood width should be no less than the width of the
¡
cooking surface. For proper performance, the housing
must cover the entire cooking surface.
For proper performance, the hood must be centered
¡
horizontally above the cooking surface. Where space is
not restricted, a wider hood can be used to increase
capture area.
3.4 Distance from cooking surface
Hood installation height above a cooktop, rangetop or
¡
range can vary.
8
The installation height ranges from a minimum height of
¡
30'' (762 mm) to a suggested maximum height of 40''
(1,016 mm). However, it is necessary to follow the
cooking appliance manufacturer's installation
instructions for proper hood height.
NOTICE:
The hood could incur some damage from heat if a
Thermador Professional® Series range or rangetop is
operated with multiple burners at high settings under a
hood that is installed at minimum clearances while the
hood is turned off.
3.5 Unit weight
This vent hood is heavy. Adequate structure and
¡
support must be provided in all types of installations.
When calculating the load for the housing support
¡
system, be sure to consider the weight of the ventilation
unit.
Description
PH30HWS
PH36HWS
PH48HWS
PH36GWS
PH42GWS
PH48GWS
PH54GWS
PH60GWS
Integral blower model VTN1DZ
Only with PH30HWS
Integral blower model VTN2FZ
NOTICE:
The supplied weights address only the ventilation unit and
blower. The installer must account for weight of any
materials of construction when calculating the total dead
weight load of installation, including but not limited to: wall,
tile, mortar, plaster, brick, finishes, partitions, and other
similarly incorporated architectural and structural items. It
is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
3.6 Support structure
Due to the weight of the hood, make sure the wood
¡
mounting bracket is attached to all available wall studs.
Wall framing should be made of 2"x 4" lumber at
¡
minimum. Proper structural support is required to
accommodate the weight of the hood.
3.7 Venting
The hood requires the ducting to be vented to the
¡
exterior of the building.
Weight
62 lbs (29 kg)
70 lbs (32 kg)
85 lbs (39 kg)
75 lbs (34 kg)
84 lbs (38 kg)
90 lbs (41 kg)
96 lbs (44 kg)
103 lbs (47 kg)
8 lbs (3.6 kg)
19 lbs (8.6 kg)