3.8 Electrical requirements
WARNING
This appliance must be properly grounded.
The appliance requires a 120V AC, 60Hz. 15A branch
¡
circuit.
The VTN2FZ blower in conjunction with a PHxxGWS
¡
requires a 20A circuit breaker.
The appliance should only be connected to a dedicated
¡
circuit (with ground) that has been installed according to
relevant regulations.
When connected to a GFCI-protected supply,
¡
Thermador Professional® Series hoods are suitable for
use in damp locations that are protected from outside
weather conditions and not subject to saturation with
water and other liquids, but can be subject to moderate
degrees of moisture, such as an outdoor covered patio
or lanai area. Refer to local codes, NEC/CEC, and/or
the Authority Having Jurisdiction (AHJ) for additional
information.
Check your local building codes for proper method of
¡
installation. This appliance should be installed in
accordance with applicable local codes or, in the
absence of local codes, with the National Electrical
Code, NFPA 70 or the Canadian Electric Code, CSA
C22.1-02.
The 25 ft. remote and in-line blower extension cable
¡
accessory (EXTNCB25W) will only work for distances
up to 25 ft. The accessory cable must be purchased
separately. DO NOT use more than one blower
extension cable per installation.
Electrical data:
¡
Refer to the rating plate for product data, including the
model and serial number.
→ "Rating plate location", Page 23