Discharging the
Capacitors
12
(16)
WARNING! An electric shock can be fatal. Danger from residual voltage from ca-
pacitors. Only work on the LT-AC-SRx PC board when the capacitors are dis-
charged.
Carry out the discharging of the capacitors
-
on each power stage set,
and
-
strictly in accordance with the following step.
Remove the four TX25 screws (10) -
11
11
(13) on the underside of the inverter.
(12)
(13)
Remove the two TX25 screws (14) -
12
(15) on the top of the inverter.
(15)
Remove the rubber edge guards (16)
13
from the left and right sides.
Lift off the inverter housing.
14
On the LT-AC-SRx PC board, switch
1
the Jumper (1) from the "RUN" position
to the "SERVICE" (3) position.
The "SERVICE" LED (2) illuminates red for
(1)
approximately 5 seconds.
When the "SERVICE" LED (2) goes out, the
capacitors are discharged.
IMPORTANT! Pay attention to the warning
label at the capacitors as well as the infor-
(2)
mation printed on the PC board.
(3)