TECHNICAL DATA
Power supply
Maximum absorbed power
Microwave power
Grill
Hot air
Microwave frequency
ELECTRICAL CONNECTION
Before connecting the appliance to the mains,
make sure that:
• the characteristics of the electrical system
satisfy what is shown on the serial number
plate applied to the front of the oven;
• the electrical system has an effective earth
connection conforming to standards and
current law.
The earth connection is required by law.
The cable must not, at any point, reach a tem-
perature greater than 50°C above the ambient
temperature.
This oven must be connected to the power sup-
ply by a supply cord fitted with an appropriately
rated plug compatible with the socket in the final
sub-circuit of the wiring powering the oven.
If a fixed appliance does not have a power cord
and plug, or another device that ensures discon-
nection from the mains with a contact opening
distance that allows for complete disconnection
under the conditions of excessive voltage cat-
egory III, such disconnection devices must be
provided by the mains power supply and must
conform to the installation rules.
The omnipolar socket or switch must be easy to
reach when the appliance is installed.
NOTE: The manufacturer declines all liability if
the usual accident prevention standards and the
above instructions are not followed.
220-240 V~,
50 Hz
3200 W
900 W
1500 W
1500 W
2450 MHz
EN 54
TYPE AND MINIMUM DIAMETER
OF THE CABLES
H05RR-F
3x1.5 mm²
H05VV-F
3x1.5 mm²
H05RN-F
3x1.5 mm²
H05V2V2-F
3x1.5 mm²
SASO
H05RR-F
3x2.5 mm²
H05VV-F
3x2.5 mm²
H05RN-F
3x2.5 mm²
H05V2V2-F
3x2.5 mm²