NOTE: the following procedures must be performed by a qualified service technician.
Problem
The machine does not cool,
or cools only partially and
the compressor is running
The machine does not cool,
or cools only partially and
the
compressor
is
running
The main power switch is
"ON" but the unit s not
running
The bowl is leaking
The
dispensing
valve
leaking
Product is flowing into drain
tray through drainage pipe
The auger is not turning
The auger is creating noise
as it rotates
Data di emissione: Dicembre, 2013
71/124

13. TROUBLESHOOTING GUIDE

Possible cause
The
space
around
inadequate for ventilation
The refrigeration system is working in
DEFROST mode
The condenser fins are clogged with
airborne particles
Fan motor is not running
Refrigerant is leaking
The electronic board is not functioning
correctly
The feeder is not functioning correctly
Electrical components of the compressor
are not functioning
not
Some
electrical
complete
The compressor is malfunctioning
The electronic board is not functioning
correctly
The feeder is not functioning correctly
The
main
cover
assembled
Some
electrical
complete
The main power switch is broken
The control board is faulty
The feeder is faulty
The compressor DC drive is faulty
The gear motor is malfunctioning
One of the bowl seal is not in place
is
The
dispensing
incompletely or incorrectly replaced in its
position
The free movement of the valve is
impeded
Dispensing valve o-rings are damaged
The bell shaped seal between the front of
the cylinder and the auger hub has not
been reinstalled properly
The bell shaped shaft seal or the spindle
bushing seal is damaged or worn
The
main
cover
assembled
Some
electrical
complete
The control board is faulty
The feeder is faulty
The compressor DC drive is faulty
The gear motor is malfunctioning
The bell shaped shaft seal has been
replaced
without
damaged
The auger has been incompletely or
incorrectly reassembled
the
machine
is
connections
are
not
is
not
correctly
connections
are
not
valve
has
been
is
not
correctly
connections
are
not
lubrication
or
is
Revisione: 5
Solution
Allow at least 20cm between the
machine and anything next to it;
keep it away from heat sources
Return to FREEZE mode
Clean the condenser fins
Check the fan motor's electrical
connections and, if disconnected,
reconnect. If still not operating,
replace the motor
Locate the leak, eliminate it and
recharge the system
Check and replace
Check and replace
Replace
the
malfunctioning
components
Check
the contacts and and
correct those incomplete
Replace the compressor
Check and replace
Check and replace
Assemble
the
main
correctly
Check
the contacts and and
correct those incomplete
Replace the switch
Replace the control board
Replace the feeder
Replace the DC drive
Replace the gear motor
Replace or reposition the seal
Reassemble and replace
Clean and lubricate the valve
and the valve cylinder with the
lubricant
provided
machine
Replace the o-rings
Find the seal and put it back in
place
Replace the damaged/worn seal
and check the condition of the
drive shaft
Assemble
the
main
correctly
Check the contacts and correct
those incomplete
Replace the control board
Replace the feeder
Replace the DC drive
Replace the gear motor
Replace or clean and lubricate
with the lubricant provided with
the machine
Check and correct
Pag. :