With the intervention of a specialized technician, eliminate any inconvenience
detected (loosened screws, burnt out lamps, etc.).
Check the outflow of water that ensues to the defrost (free the drips, clean any
filters, check the siphons, etc.).
Dispose of defrosted water or water used for washing through the drains or
purification system in accordance with current legislation as this may come
into contact with pollutants due to the nature of the product, any residue,
accidental breakages of casing containing liquids and the use of non-
permitted detergents.
If abnormal condensation forms, inform the refrigeration technician
immediately.
Carry out all preventive maintenance operations punctually.
Replace the lamps with new identical ones.
The cabinet must be installed by technicians trained and authorised by the
body indicated in the contract.
DO NOT use the cabinet barefoot
DO NOT touch the cabinet with wet or damp hands and feet.
DO NOT remove protective covers or panelling that require the use of tools to
remove them therefore DO NOT remove the electrical panel cover. These
operations must always be carried out by specialised technicians.
DO NOT obstruct the air inlet passages.
DO NOT use spotlights with incandescence lamps aimed directly on the
cabinet. Danger: overheating the merchandise.
Prevent solar irradiation from hitting directly on the goods displayed. Danger:
alteration of the goods.
DO NOT introduce explosive substances with inflammable propellant
(e.g. spray cans) etc. Danger: explosion
DO NOT load the glass shelves with beverages
Limit the temperature of the irradiating surfaces that are present in the sales
area, for example, by insulating the ceilings.
IN CASE OF A GAS LEAK OR FIRE OUTBREAK
Do not stay in the room where the cabinet is located if it is not
appropriately ventilated. Disconnect the cabinet by acting on the main
switch upstream of the device.
DO NOT USE WATER TO EXTINGUISH THE FLAMES, BUT DRY
EXTINGUISHERS ONLY.
ANY OTHER USE NOT EXPLICITLY POINTED OUT IN THIS MANUAL MUST BE
CONSIDERED DANGEROUS. THE MANUFACTURER CANNOT BE DEEMED
RESPONSIBLE FOR POSSIBLE DAMAGES STEMMING FROM AN IMPROPER,
INCORRECT, AND UNREASONABLE USE.
USEFUL NUMBERS: Switchboard +39 0499699333 - FAX +39 9699444 - Call Centre 848
800225
4. Purpose of the manual/Field of application - Subjects concerned
This instructions manual contains the description of the line of refrigerated
cabinetsGinevra 2 manufactured by ARNEG Spa.
The information that follow have the purpose of providing indications with regards to:
use of the cabinet
technical characteristics
installation and assembly
information for the personnel appointed to its use
maintenance interventions
safety indications
The manual is part of the cabinet, keep it for the entire duration of the same.
The manufacturer deems itself absolved of any responsibility in the following
cases:
05060155 00 28/11/2013
Ginevra 2
English
25

Publicidad

loading

Este manual también es adecuado para:

Ginevra 2 h125Ginevra 2 h150