9.1. Faults Display
Code
Clock Error
RTC
The device will not store date and time when
the HACCP alarm appears
CABINET
PROBE
Probe Error
EVAPORATOR
The type of probe is incorrect.
PROBE
The probe is defect.
The probe - electronic card connection is
CONDENSER
incorrect.
PROBE
The temperature detected by the probe is
beyond the limits allowed by the cell probe in
use.
NEEDLE
SENSOR 1
THERMAL
Evaporator Baffle Error
SWITCH
The evaporator fan baffle has been opened.
Door Open
DOOR
The door is open. If the alarm persists, verify the
OPEN
door micro switch alignment
HIGH
HACCP temperature alarm.
TEMPERATURE
The temperature measured by the room probe
has exceeded the limit imposed by its
LOW
parameters.
TEMPERATURE
Duration of Blast Chilling
CYCLE
DURATION
The blast chilling / freezing cycle ended beyond
the maximum duration allowed (HCCP alarm)
BOARDS
Interface communication error user- control
COMMUNICATIONS
module.
BOARD
Interface compatibility error user- control
COMPATIBILITY
module.
Causes
53
ENGLISH
Solutions
Set the current date and time
Contact the after-sales
service.
 Make sure the probe is of
kind PTC.
 Verify the integrity of the cell
probe.
 Verify the accuracy of the
connection instrument -
probe.
Check that the temperature near
the cell probe is not beyond the
established limits
Contact the after-sales
service.
Close the evaporator fan baffle.
Contact the after-sales
service.
 Air the room.
 Clean the condenser.
Check that the fans are
working properly.
 Verify the cell temperature
Check the product quantity inside
the blast chiller.
Contact the after-sales
service.
Contact the after-sales
service.
GB

Publicidad

loading

Este manual también es adecuado para:

6t5t 1/15t 1/1 700