5.4.4 FT-X with a Non-Overhead Anchorage Leading Edge Anchorage Application
[310 to 420 lbs. (141 to 191 kg) user]
The leading edge/below D-ring condition minimum required fall clearance (MRFC) is calculated using
five metrics, measured from the walking-working surface: SRD Deceleration Distance, D-Ring Shift and
Harness Stretch [1 ft (0.3m)], Safety Factor [1.5 ft (0.5m)], Dorsal D-ring Height [5 ft (1.5m)], and Swing
Fall. Dorsal D-ring height is added to account for the below D-ring tie-off compared to the overhead
condition.
Figure 12 - MRFC Overhead Anchorage
.5
Y- Lateral
28.0
Figure 14 - FT-X Minimum Required Fall Clearance for 310 to 420 lbs. (141 to 191 kg) Users
Z- Minimum Required
Fall Clearance From
Working Surface
6.0 Maintenance, Service, and Storage
6.1 Maintenance:
Ensure the SRL is kept free of excess paint, grease, dirt or other contaminants as this may cause
the lifeline or retracting mechanism to malfunction. Ensure no debris enters the housing. Clean the
exterior of the unit as required with a detergent/water solution. Do not allow water or other corrosion
14
X-SRD Anchorage Height
Above Dorsal D-ring
Z- Minimum Required
Fall Clearance From
Working Surface
1
2
.5
Y- Lateral
28.0
Figure 13 - MRFC Non-Overhead Anchorage
Z- Minimum Required
Fall Clearance From
Working Surface
Figure 4 - MRFC Non-Overhead Anchorage
1 foot (0.3 m)
increments along the
X-Axis represents the
Horizontal Distance
to Anchorage the
user is working away
from the SRD
Example 1:
If the user is working 3 feet (0.9 m) away from
Z- Minimum Required
the SRD, and the SRD is anchored between the
Fall Clearance From
Working Surface
user's Dorsal D-Ring or up to 4.0 ft (1.2 m) above
the D-Ring. Minimum required fall clearance is 11
feet (3.4 m) including swing fall.
Example 2:
If the user needs to work 4 feet (1.2 m) away from
the SRD along the edge, and the SRD is anchored
at foot level, the minimum required fall clearance
is 22 feet (6.7 m) including swing fall.