Device connections, bottom
Fig. 5: Bottom device connections overview
6
USB1
7
USB2
8
ETH 0
9
ETH 1
10
RS485/CAN (J1000) (not assigned)
11
Power supply (J102), 24 V (DC)
12
Relay (J900) (not assigned)
13
Relay (J901) (not assigned)
g Refer to chapter "Connector overview" on page
9.
Installation and connection
Connector overview
The overview of the device connections ((Fig. 4),
(Fig. 5)) shows the connection position of the plug
connectors that are used for current converters, volt-
age measurement, relay contacts and communica-
tion. The pin position is shown graphically for each
plug connector type. The tables show the pin assign-
ment with the corresponding signal.
g Refer to chapter "Device connections overview" on
page 8.
Plug connector current measurement
Information
Be sure to write down the connection positions of
the current converters, the type of the current con-
verters, their phase assignment and the rated current
of the phase fuse, as they will be queried later during
the configuration of the energy manager (installation
wizard for the web application).
Parameter
Value
Connectors
J200/Y300/Y301
Manufacturer
Phoenix Contact
Bushing part number
1786853
Connector part number
1790124
Installation and connection
Connector overview J200/J300/J301
The plug connectors of the current converters (J200,
J300, J301) are identical in construction and can be
connected variably in one of the terminals ((Fig. 4
2/3/4)) provided for this purpose.
Fig. 6: Overview J200/J300/J301
PI
Current converter
N
J200
J300
J301
1
1
5
9
2
1
5
9
3
2
6
10
Code
"l",
black
"k",
white
"l",
black
9