Descargar Imprimir esta página

Cameo ZENIT W300 TW Manual De Usuario página 17

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 88
to warm white (CCT) and the brightness (Dim) of the light directly on the device. Press MODE to
access the main menu (--- Menu ---). Using UP and DOWN, select the menu item Stand Alone
and confirm with ENTER, then select Static and confirm once again with ENTER. Now use UP and
DOWN to select the menu item you wish to edit (observe arrow) and confirm with ENTER. The dis-
play will show a three-digit number field and you can use the UP and DOWN controls to configure
the desired value. Confirm with ENTER.
STANDALONE MODE USER PRESETS (User Color)
The User Presets operating mode makes it possible to store the overall brightness, strobe and a
mixture of warm white and cold white directly in the device in five individual presets. Press MODE
to access the main menu (--- Menu ---). Now select the Stand Alone menu item, confirm with
ENTER, then select User Color and confirm the entry again with ENTER. Use UP AND DOWN to
select one of the stored presets Color1 to Color5 and confirm with ENTER and select the submenu
item you want to edit (observe arrow). Confirm with ENTER. The display will show a three-digit
number field and you can use the UP and DOWN controls to set the value as required between
000 and 255. Confirm all entries with ENTER.
TIMER FUNCTION (Timer)
The timer function allows the standalone modes Static, CCT and User Color to be timer controlled
in such a way that the fade-in time can be set from 0 to 60 minutes, the dwell time from 1 to 24
hours and the fade-out time from 0 to 60 minutes. The timer starts immediately after activating
the timer function in the previously activated standalone mode and remains active even if the
spotlight is switched off and restarted. Press MODE to access the main menu (--- Menu ---).
Using UP and DOWN, select the menu item Stand Alone and confirm with ENTER, then select
Timer and confirm once again with ENTER. For the individual timer control settings, select Fade
In, Dwell Time or Fade Out (observe arrow) and confirm with ENTER. The display will show a
three-digit number field in each case. Use UP and DOWN to set the value as required from 000 to
060 or 001 to 024. Confirm by pressing ENTER again. Once all settings have been configured as
required, activate the timer function by selecting the submenu item Timer On/Off using UP and
DOWN, confirm with ENTER, select On and confirm again with ENTER (to deactivate the timer
function, please select Off and confirm).
17

Publicidad

loading

Este manual también es adecuado para:

Clzw300tw