4 lines for inserting the workshop information;
-
3 lines for inserting the operators' names;
-
a keypad for setting characters.
To save the set data, select the Save button
.
To quit the programme, select the Exit button
.
Note
Each line for storing the workshop data consists
of a maximum of 28 characters.
Each line for storing the operators' names consists
of a maximum of 14 characters.
Note: If connected to a printer, the stored cus-
tomisation data will be printed in the relative
reports.
6.2. Wheel balancer parameter configuration
Modifications to factory settings normally are not
required. However, if necessary, the machine sta-
tus and/or the operating mode can be modified.
Each parameter can be modified using the arrow
keys
The parameters that can be modified are:
1. Language:
-
to set the preferred language
2. Clock:
-
to set the current time
3. Year:
-
to set the current year
4. Month:
-
to set the current month
5. Day:
-
to set the current date
6. Timeout screensaver:
-
to set the waiting time before the main logo
is displayed
7. Radial runout threshold (1st harmonic):
-
to set the threshold that displays the meas-
ured value in red
8. Radial runout threshold peak-to-peak:
-
to set the threshold that displays the meas-
ured value in red
74
.
EYELIGHT Plus DiagnosticLine - Operator's manual
9. Lateral runout threshold (1st harmonic):
-
to set the threshold that displays the meas-
ured value in red
10. Lateral runout threshold peak-to-peak:
-
to set the threshold that displays the meas-
ured value in red
11. Tread height threshold:
-
to set the threshold that displays the meas-
ured value in red
12. Wheel side slip threshold:
-
to set the threshold that displays the meas-
ured value in red
13. DIAGNOSIS CYCLE:
-
to activate the eventual diagnosis of the wheel:
OFF diagnostic cycle disabled
1 - FAST acquisition of radial eccentricity of the
complete wheel
2 - FULL radial eccentricity acquisition of the
complete wheel and rim
3 - PRO Including radial eccentricity of the
complete wheel and rim in addition to the
outboard rim of the rim, tread height and
possible wheel drift
14. OPT warning:
-
to display the alarm indicator light in the main
working screen
15. Disable laser:
-
to disable the lasers when faulty. If disabled,
the dimensions must be set manually and the
weights applied in the 12 o'clock position
16. Automatic position search (RPA):
-
to enable automatic position search at the
end of the spin (YES enabled – NO disabled)
17. measures dimensions with release of the
automatic clamping system:
-
to set the automatic measurement of the
dimensions every time the automatic clam-
ping system is activated (YES active – NO
deactivated)
18. Hidden Weight automatic
-
to activate Hidden Program in automatic mode
(YES active - NO disabled)
If the program is disabled, it is possible to run
the Hidden Weight program in manual mode.

Publicidad

Tabla de contenido
loading