Descargar Imprimir esta página

Tripp-Lite APSWX Serie Manual De Instrucciones página 17

Ocultar thumbs Ver también para APSWX Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Operation
Program Code Function
02
Output Voltage
03
Output Frequency
04
Battery Type
Bulk Charge
05
Voltage
Floating Charge
06
Voltage
07
Low Voltage Alarm
Selectable Options
Description
220V AC
230V AC (Default)
To take effect, the system must be restarted in order to
change the output voltage.
240V AC
50 Hz (Default)
To take effect, the system must be restarted in order to
change the output frequency.
60 Hz
AGM (Default)
If you choose to use Absorbed Glass Mat (AGM) or
Sealed Lead-Acid (SLA) deep cycle batteries, the
default setting of "AGN" should selected.
Flooded
If you choose to use flooded deep-cycle marine
batteries, set the battery type to "FLd".
No Battery
If the inverter application is without battery, program
code 04 must be set to "Nbt".
User-Defined
If "User-Defined" is selected, the battery charge voltage
and low DC cutoff voltage can be set up in programs 05
and 06.
48V Model Default
48V model: 56.0V DC (default)
Setting: 56.0
Setting range: 48V to 60V
Setting increase or decrease of 0.1V.
Note: If self-defined is selected in program 04, this program
can be set up.
48V model: 54.0V DC (default)
48V Model Default
Setting range: 48V to 60V
Setting: 54.0
Setting increase or decrease of 0.1V.
Note: If self-defined is selected in program 04, this program
can be set up.
48V Model Default
48V model: 44.0V DC (default)
Setting: 44.0
Setting range: 36V to 50V
Setting increase or decrease of 0.1V.
17

Publicidad

loading

Este manual también es adecuado para:

Apswx4kp48vmpptApswx6kp48vmpptAg-057dAg-057e