4. Operation
Program Code Function
Low Voltage
08
Shutdown
Solar Energy
09
Feed to Grid
Configuration
10
AC Charger
Single and Parallel
11
Configuration
Modes
AC Input Voltage
12
Range
Selectable Options
Description
48V Model Default
48V model: 42.0V DC (default)
Setting: 42.0
Setting range: 36V to 50V
Setting increase or decrease of 0.1V.
Disable (Default)
Solar energy feed to grid is disabled by default.
Enable
Solar energy feed to grid is enabled.
The AC charge rate can be set from 0A to 60A in 10A
30A (Default)
increments.
Note: When set to 0A, if the Solar and Utility exist at the same
time, the solar energy will charge only the battery, and the load
will be powered by utility. The grid-tie function is not available in
this mode.
Single (Default)
Single enable.
Single-Phase Parallel
Single-phase parallel enable.
A-Phase
A-Phase parallel enable.
B-Phase
B-Phase parallel enable.
C-Phase
C-Phase parallel enable.
Notes:
• When enabling 3-phase parallel, make sure A-phase is the host.
• After the parallel parameters have been modified, the device must be restarted to take
effect.
APL (Default)
If selected, acceptable AC input voltage range will be
within 120-280V AC.
UPS
If selected, acceptable AC input voltage range will be
within 170-280V AC.