In Cardio mode, the tension will be adjusted automatically to an
insensitivity in where your hart rate reaches the Pre set HRC target.
Watt Mode�
- Use Dial Up/ Down function to select workout program, Select Watt
Control ( W ),
confirm by press MODE.
- Use Dial Up/ Down function to set the Watt target: 120 is pre-set
default ( 10~350 )
confirm by press MODE.
- Use Dial Up/ Down key to pre-set training time,
confirm by press MODE.
- Press START/ STOP key to start workout
- Use RESET, to go back to main menu.
In Watt mode, the tension will be adjusted automatically to an
insensitivity in where the Watt reaches the Pre set Watt target.
‼ NOTE
•
The Watt parameter is a calculation of RPM and Tension level.
When RPM is higher, the tension will be lower.
When RPM is lower, the tension will be higher.
User Profile
- Use Dial Up/ Down function to select workout program, Select User
Profile ( U ),
confirm by press MODE.
- Use Dial Up/ Down function to set the tension level for the first profile
segment.
confirm by press MODE.
- Repeat the rest of the profile segment tension levels too in the same
manner.
- Press and hold MODE button for 2 seconds to confirm and store the
set User Profile.
- Use Dial Up/ Down key to pre-set training time,
confirm by press MODE.
- Press START/ STOP key to start workout
- Use RESET, to go back to main menu.
In User Program profile mode, the tension will be adjusted automatically
to the pre set profile.
The duration of each segment in the profile is 1/8 of your pre set
training time.
‼ NOTE
•
There is one user program available per user.
Recovery
- The RECOVERY key will only be valid if pulse is detected.
- TIME will show „0:60" (seconds) and counts down to 0.
- Computer will show F1 to F6 after the countdown to test heart rate
recovery status. User can find the heart rate recovery level based on
the chart below.
- Press RECOVERY key again to return to the beginning.
F1
Outstanding
F2
Excellent
F3
Good
F4
Fair
F5
Below average
F6
Poor
Body Fat
- Press the BODY FAT key to start body fat measurement.
- During measuring, users have to hold both hands on the hand grips.
LCD display "-" "- -" "- - -" "- - - -" for 8 seconds until computer
finish measuring.
- LCD will display BMI and FAT %.
Body fat mode error codes
- *E-1
There is no heart rate signal input detected.
- *E-4
Occurs when FAT% and BMI result is below 5 or exceeds 50.
Bluetooth & APP
- This console can connect with an APP on a smart device by Bluetooth
(iOS & Android).
- Establish the Bluetooth connection only via the connection mode on
the installed APP on your smart device.
- When the bluetooth connection between APP and console is
establisched the console display will be dimmed.
‼ NOTE
•
Tunturi only provides the option to connect your fintess console
throughout a blue tooth connection. Therefore Tunturi cannot be
held resposible for damage, or malfunctioning of products other
than Tunturi products.
•
Check the website for extra information.
This console can receive a Bluetooth heart-rate transmitter. There is no
need to pair the device, as the console will auto detect the heart-rate
transmitter when it is in range.
Cleaning and maintenance
The equipment does not require special maintenance. The equipment
does not require recalibration when it is assembled, used and serviced
according to the instructions.
⚠ WARNING
•
Do not use solvents to clean the equipment.
- Clean the equipment with a soft, absorbent cloth after each use.
- Regularly check that all screws and nuts
are tight.
- If necessary, lubricate the joints.
Defects and malfunctions
Despite continuous quality control, defects and malfunctions caused
by individual components may occur in the equipment. In most cases
it's unnecessary to take the whole device in for repair, as it's usually
sufficient to replace the defective part.
2 3
English