8.3
Generating set identification
The generating set identification plate is affixed to the outside of the enclosure.
(B)
(N)
Serial numbers will be required when requesting troubleshooting advice or spare parts.
To keep them safe, note down the serial number of the generating set below.
Generating set serial number:......../.............. - ........................ - .........
8.4
Specifications
Model
Maximum power
Rated output
Acoustic pressure at 1 m
Acoustic measurement uncertainty
Engine type
Maintenance kit
Fuel tank capacity
Recommended fuel
Recommended oil
Oil sump capacity
Oil cut-out*
Direct current
Alternating current
Circuit breaker(s)**
Socket type
Spark plug type
Battery
Dimensions l x w x h
Weight (without fuel)
o: standard
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the
event of an overload and/or short circuit, the supply of electrical energy may be cut. If necessary, replace the circuit breakers in the generating set
with circuit breakers with identical nominal ratings and specifications.
8.5
Recommended fuel quality
Using fuel which does not comply with the following specifications exposes the equipment to irreversible damage not covered under
warranty:
-
Cleanliness and quality: ensure that the petrol used does not contain water and that it is fresh and clean (not out of date or
contaminated). For the
-
Octane rating: minimum octane rating of 87 (R+M)/2 or minimum octane rating of 90 (RON = Research Octane Number)
-
Blends: the use of unleaded petrol containing up to 10% ethyl alcohol is authorised (France: SP95-E10). It is not permitted
to use unleaded petrol containing less than 90% petrol, e.g. E15, E20 or E85. Blends of methyl tert-butyl ether (MTBE) and
unleaded petrol are approved (up to a maximum of 15% MTBE by volume).
However, it is strongly recommended that the same type of fuel is used throughout the complete service life of the unit. If the unit is
used infrequently (less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank.
279_EN.docx
(A)
(G)
(C)
(G)
(D)
(E)
(H)
(F)
(L)
(M)
INVERTER PRO 2000 C5
Unleaded petrol
1 x 2P-230V-10/16A + 12V-8A
330830019
49 x 28 x 44,5 cm
23/178
(A): Model
(C): Maximum
power
(E): Power factor
(I)
(G): Current
(J)
amperage
(I):
(K)
voltage
(K): Reference
standard
(M):
(N):
2000W
1600 W
75 dB(A)
0,70 dB(A)
MZ80_C5
RYS2
4,2L
10W30
0,4 L
O
12V - 8A
230V - 7A
O
X
21 kg
x: not available
Example of an identification plate
(B): CE marking
(D): Nominal power
(F): Earth
(H): Current
frequency
Current
(J):
Protection
index
(L):
Serial number
Guaranteed acoustic power level
UKCA marking
INVERTER PRO 2000 UK C5
2000 W
1600W
75 dB(A)
0,70 dB(A)
MZ80_C5
RYS2
4,2 L
Unleaded petrol
10W30
0,4 L
O
12V - 8A
230V - 7A
O
1 x 2P- 230V-13A + 12V-12A
330830019
X
49 x 28 x 44,5 cm
21kg