5. For EVC22-3AC-10, check that there is no voltage
between L1 and grounding conductor, L2 and
grounding conductor and L3 and grounding
conductor at the terminal block for connecting the
utility grid. Use a suitable measuring device for this
purpose.
For EVC7.4-1AC-10, check that there is no voltage
between L1 and grounding conductor at the
terminal block for connecting the utility grid. Use a
suitable measuring device for this purpose.
Operating manual
9 Disconnecting the product from voltage sources
EVC22-3AC-10
0 . 0 0
0 . 0 0
EVC7.4-1AC-10
0 . 0 0
0 . 0 0
EVCxx-10-BE-en-11
L 1 L 2
L 3
N N
P E
L 1 L 2
L 3
N N
P E