Message, cause and corrective measures
Communication error in inverter bridge
The product has detected an internal communication error.
Corrective measures:
• Contact the Service.
Communication fault with meter unit
The product is not receiving any data from the external energy meter.
Corrective measures:
• Ensure that the energy meter is integrated into the same network as the
product (see energy meter manual).
• For Wi-Fi connection: Improve the Wi-Fi connection quality (e.g., via Wi-Fi
repeater) or connect the product with the DHCP server (router) via
Ethernet.
Communication to internal energy meter disturbed
The product has detected a communication error of internal energy meter.
Corrective measures:
• Contact the Service.
Relay defect
Grid relay of the product is defective.
Corrective measures:
• Contact the Service.
Invalid spec. for |##| from |##|
An invalid specification for reactive or active power has been set by the ana-
log inputs, the digital inputs or Modbus.
Corrective measures:
• Check and modify reactive and active power setpoints in the user
interface of the product.
Fast stop
An overcurrent has been detected at the connection point. This triggered a fast
stop.