Strain
J
ReJief
[
....
PJate
i
Figure 27
Electricam Connection
ELECTRICAL
CONNECTmON
,_
WARNmNG: ELECTRICAL
SHOCK
HAZARD
- Working
on an energized
circuit
could
result
in serious
injury
or death. Only
qualified
e_ectricians
shouM
perform
ebctrbal
work. Do not
attempt
any work on the dishwasher
electric
supply
circuit
unti_ you are certain
the circuit
is de-energized.
,_
WARNmNG: FIRE HAZARD
-
mmproper electrica_
work can cause fire. Only
qualified
e_ectricians
should
perform
e_ectri-
ca_ work.
Grounding
instructions
The dishwasher must be properly grounded before
operating, This appliance must be connected to a
grounded metal permanent wiring system, or an equipment
grounding conductor must be run with the circuit
conductors and connected to the equipment grounding
terminal or lead on the dishwasher, Make sure that the
dishwasher is connected to a suitable ground in
compliance with all local codes or, in the absence of a
local code, with the NATIONAL ELECTRICAL CODE in the
United States or the CANADIAN ELECTRIC CODE C22,1 -
latest edition in Canada as well as any provinciaVstate or
municipal or local codes that apply,
1) Retrieve the strain relief plate, and install a strain relief
(not supplied) into the opening on the strain relief plate,
NOTE: Orient the strain relief as shown in Figure 26,
2) Pass the electrical supply cable through the strain relief,
as shown in Figure 27, Leave 3 - 4 inches of insulated wire
extending through the strain relief plate,
3) Tighten the strain relief screws,
4) Slide the strain relief plate into the junction box, and
secure it to the junction box with the supplied screw,
(Continued on next page)