2. Installing the battery.
Do not operate the push lever or trigger while
installing the battery.
Latch
Push
WARNING
Never leave the Stapler with the battery attached.
This could result in an accident.
Make sure the LED light is not blinking.
If the LED light is blinking, the battery doesn't have
enough power and it needs to be charged.
3. Remove the finger from the trigger and press the
push lever against the workpiece.
THE NAILER MUST NOT OPERATE.
Do not pull the trigger
Depress push lever
4. Separate the push lever from the workpiece. Next,
point the nailer downward, pull the trigger and then
wait in that position for 5 seconds or longer.
THE NAILER MUST NOT OPERATE.
Handle
Battery
Insert
Pull out
Pull the trigger
[Time out function]
Press and hold the push lever for at least 4 seconds
to enter time out mode. The LED will blink to indicate
time out mode.
The brad nailer is disabled in time out mode.
To return to normal mode, release the push lever or
lift the tool from the wood surface.
LED light
5.
(1) Without touching the trigger, depress the push lever
against the workpiece.
Next, pull the trigger.
THE NAILER MUST OPERATE.
(2) Hold the trigger back and depress the push lever
against the workpiece again.
THE NAILER MUST NOT OPERATE.
(3) Separate the finger from the trigger. Next, (1) is
operated again.
THE NAILER MUST NOT OPERATE.
6. If no abnormal operation is observed, you may load
nails in the Nailer.
Drive nails into the workpiece that is the same type to
be used in the actual application.