Descargar Imprimir esta página

Walter SURFOX MAX Serie Manual Del Usuario página 22

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical installation
5.2.
Make sure you have read and checked all the precautionary notes in chapter 5.1.
• Prepare the DW wand by installing the most suitable accessory for the type of work to be carried out (see chapter 4).
• Connect the ground cable connector (A) to the red socket on the front panel of the unit.
• Use the crocodile terminal of the ground cable (B) to grip the piece of stainless steel to be treated.
• Use the supplied cable to carry out the electrical installation of the DW wand; connect the female connector (C) to the DW
wand (D) and insert the male connector into one of the designated black sockets on the front panel of the unit (E).
• The SURFOX MAX can operate with two wands at the same time. When using a single wand, choose one or the other
socket indifferently.
• Connect the device power cord to a suitable socket.
22
B
A
E
C
D