OPERATION
FIG. 20
A
G
I
A - 120 Volt AC 20 A receptacles
B - 120/240 Volt AC 30 A receptacle
C - 120/240 Volt AC 50 A receptacle
D - Parallel operation outlets
E - ECO mode switch
F - Reset button
G - 20 A circuit breaker
STARTING THE ENGINE: PROPANE
DANGER
ways turn the propane tank valve to the fully closed
position if not running the generator on propane.
l Make sure the LPG/propane hose is correctly connected
to the generator and propane tank.
l Turn the fuel selector switch to propane operation. (See
Figure 18.)
l Fully open the valve on the propane tank.
l Be sure the ECO mode switch is in the OFF position.
l Place the battery switch in the ON position.
l Choose the starting method:
 •  R emote Start: Push and hold the ON button on the
remote start key fob for one second.
 •  P ush-ButtonStart:Push and hold the engine START/
STOP button for two seconds.
 •  R ecoil Start: Firmly grasp and pull the recoil handle
slowly until you feel increased resistance, then pull
rapidly.
NOTE: In extreme cold, manually close the choke by
moving it right toward the front handle of the generator.
NOTE: During Push-Button or Remote Start the engine will
automatically set the choke and begin the start sequence.
22 | English
B
C
U
H - Smart switch connector (not included)
I - 30 A circuit breaker
J - Ground terminal
K - Low oil LED
L - Overload LED
M - Output ready LED
N - Digital display
Fire and explosion hazard. Al-
D
O
P
N
K
L
M
H
E F
J
O - Service generator LED
P - Automatic shutoff LED
Q - Propane hose connection
R - Battery switch
S - Fuel selector switch
T - START/STOP button
U - 50 amp circuit breaker
If the engine fails to start, the generator will attempt to start
the engine two more times.
STOPPING THE GENERATOR
See Figure 20.
l Remove any connected loads from the control panel
receptacles.
l Allow the generator to run at "no load" to reduce and
stabilize engine and alternator temperatures.
l Stop the flow of fuel.
•  For gasoline, close the fuel valve.
•  For propane, close the cylinder valve on the LP gas
cylinder.
l Use one of the following to turn off the generator:
•  Press the OFF button on the remote.
•  Press the START/STOP button on the control panel.
l Place the battery switch on the control panel in the OFF
(O) position.
l Disconnect the propane hose from the LP gas cylinder
and the generator.
To stop the unit quickly in an emergency:
l Place the battery switch in the OFF (O) position.
T
Q
S
R