It is necessary to read software inside the new control
unit by means of a SD card, if the control unit has
been exchanged.
The software is placed on a SD card which must
contain the folders and one or more of the files as
shown below. The folder names must be saved in BIG
letters and with the original names.
Software reading
• Insert the SIGMA SD-card in the slide in the right
side of the machine.
• Turn on the machine.
• The display flashes shortly with six lines.
• Wait until the set current is displayed.
• Turn off the machine and remove the SD card
• The machine is now ready for use.

SOFTWARE

All machine user settings are deleted when
the file 106454xx.bin has been inserted. There-
fore, always remove the SD-card from the
machine after the software update. Thereby,
continuous software update is avoid each time
the machine is turned on.
If the SD-card contains software for other units e.g.:
10020115.cry
10020113.cry
These units will be updated if they are connected to
the CAN network.
Please note that this update will be longer in time, so
please do not turn off the machine until the standard
control panel will be displayed at SIGMA.