Error codes for welding program package
106454xx.bin
Error code
Cause and solution
There is no welding programs
present in the control unit
• Insert a SD card with software
in the control unit and turn on
the machine. See page 23.
SD card is not formatted.
• The SD card must be formatted
in a PC as FAT or use another
SD card.
It is only possible to have one file
with welding programs.
• Make sure that there is only one
file with the number
106454xx.bin on the SD card.
See page 23.
The welding program package
does not match this control unit.
• Use a SD card with software
that matches your control unit.
The welding program package is
locked for another control unit
with another serial number/ bar
code.
• Your software package is copy
protected and cannot be used
for a control unit without the
correct license.
The control unit is defective
• Contact MIGATRONIC Service.
The file 106454xx.bin is not
present on the SD card.
• See page 23.
The file 106454xx.bin has an
error.
1. Insert the SD card in the
machine again.
2. Exchange the SD card.
The Sigma folder with files are
not present at the card or are
saved incorrectly.
1. Make a folder
MIGA_SW / SIGMA as
described on page 23 and save
the files in the folder.
2. Exchange the SD card
The internal memory is to small
• Welding program package
cannot be loaded
Error codes for Power control package 10001702.cry
Error code
Cause and solution
The file 10001702.cry has an
error.
1. Insert the SD card in the
machine again.
2. Exchange the SD card.
SD card is not formatted.
• The SD card must be formatted
in a PC as FAT. Or use another
SD card.
The software does not match this
control unit.
• Use a SD card with software
that matches your control unit.
DSP-PCB is defective
• Contact MIGATRONIC Service
Data transmission error
• Turn on and off the machine.
Exchange the SD card if the
error is displayed again. Contact
your dealer if necessary.
The file 10001702.cry has an
error.
1. Insert the SD card in the
machine again.
2. Exchange the SD card.
DSP-PCB is defective
• Contact MIGATRONIC Service
28