Descargar Imprimir esta página

Error Codes - Migatronic SIGMA2 300 Compact Manual De Instrucciones

Ocultar thumbs Ver también para SIGMA2 300 Compact:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
One of the following mentioned error codes will be displayed if an error occurs during software update.
Error code
Cause and solution
There is no software present in
the control unit.
• Insert a SD card with software in
the control unit and turn on the
machine.
SD card is not formatted.
• The SD card must be formatted
in a PC as FAT and place the
files down on the card or use
another SD card.
SD card contains no software.
• See page 23.
SD card has more files of the
same name.
• See page 23.
The control unit has tried to read
more data than is accessible in
the memory.
1. Insert the SD card again.
2. Replace the SD card.
3. Contact MIGATRONIC Service.
Software on the SD card is
locked for another type of control
unit.
• Use a SD card with software
that matches your control unit.
Software on the SD card is
locked for another control unit
with another serial number/ bar
code.
• Use a SD card with software
that matches your control unit.
The internal copy protection
does not allow access to the
microprocessor.
1. Insert the SD card in the
machine again.
2. Contact MIGATRONIC Service.
The memory circuit is defective
in the control unit.
• Contact MIGATRONIC Service.
The memory circuit is defective
in the control unit.
• Contact MIGATRONIC Service.
The file 10001801.cry has an
error.
1. Insert the SD card in the
machine again.
2. Exchange the SD card.

ERROR CODES

Error codes for MWF software 10001801.cry
27
Error code
Cause and solution
Lacking communication to the
power source
1. The power source is a MK1
version and cannot
communicated with wire feed
unit MK2 version.
2. The intermediary cable is
damaged.
3. Insert the SD card in the
machine again.
4. Contact MIGATRONIC Service.

Publicidad

loading