Descargar Imprimir esta página

Fiorenzato XGi Serie Manual Del Usuario página 36

Ocultar thumbs Ver también para XGi Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 253
Series
5
USING THE GRINDER-DOSER
5.1 Machine controls
The grinder-doser is controlled by the On/Off switch (see paragraph 5.1.1) and an
operator control panel with a TOUCH-type display, for selecting and setting all the
operating functions of the appliance (see paragraph 5.4). All information on the
operating status of the appliance, working parameters and commands that can be
given are shown on the display on the front of the machine. All the command and
signalling devices on the grinder-doser are described below.
The grinder-doser is delivered with a
calibrated by the manufacturer. The weighing system can only be calibrated
again (if required) by the specialised technicians of the manufacturer and/
or its authorised retailers, who are in possession of the "Administrator
Password", thereby allowing access to the reserved pages of the grinder-
doser management system.
5.1.1
Switch
Switches the appliance on and off.
Turned to the "O" position: appliance
off (power supply disconnected).
Turned to the "I" position: appliance
on (electrically powered).
Fiorenzato |
Series_00 Ed. 04/2022
EN
weighing system already correctly
17 / 49
EN
5.2 Preparing to use the grinder-doser
When installation has been completed, the machine is ready for use and can be loaded
with coffee beans to be ground. With reference to Fig. 11, to load coffee beans it is
necessary to:
Place the hopper (Part 1) on the
grinder-doser (Part 2) and lock it into
the operating position by tightening
the
appropriate
fastening
screw
(Part 3).
Ensure that the locking slide (Part 4)
is completely closed.
Remove the lid (Part 5) and fi ll the
hopper with the roasted coffee beans
to be ground.
Close the hopper with its lid (Part 5).
Gradually open the locking slide (Part
4) to allow the coffee beans to fall into
the grinding chamber.
Switch on the grinder-doser by
turning the appropriate switch to the
"I" (ON) position (Part 6).
After a few seconds, the display
shows the "Confi rm Start-up" page
and waits for the user to carry out
the
"Initial
Start-up"
procedure
(§5.3) required in order to make the
weighing
system
operational,
which is enabled by default when the
appliance is fi rst switched on.
18 / 49
Series
5
1
4
3
2
6
Fig. 11
Fiorenzato |
Series_00 Ed. 04/2022

Publicidad

loading

Este manual también es adecuado para:

F64 e xgiF64 evo xgiF83 e xgiF71 ek xgi