rating plate or connect it directly to the electrical mains. In the latter case, a single
pole switch must be placed between the hob and the mains, with a minimum
opening between the contacts of 3 mm in compliance with current safety codes
(the earthing wire must not be interrupted by the switch). The power supply cord
must be positioned so that it does not reach a temperature in excess of 50 °C than
room temperature at any point.
Before actual connection make sure that.
Before actual connection make sure that:
•
The fuse and electrical system can withstand the load required by the hob;
•
The electrical supply system is equipped with an efficient earth hook-up
according to the norms and regulations prescribed by law;
•
The plug or switch are easily accessible.
Important: the wires in the main lead are coloured in accordance with the
following code:
•
Green & Yellow - Earth
•
Blue - Neutral
•
Brown - Live
As the colours of the wires in the main lead may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
•
As the colours of the wires in the main lead may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked "E" or
Green or Green & Yellow.
•
Connect the Brown wire to the terminal marked "L" or coloured Red.
•
Connect the Blue wire to the terminal marked "N" or coloured Black.
or coloured
EN
59