  OUTDOOR UNIT INSTALLATION 
Step4: Install Wiring 
4.1
Use a phillips screwdriver to unscrew wiring cover, grasp and press it down gently to take it down. 
4.2
Unscrew the cable clamp and take it down. 
4.3 By following the WIRING DIAGRAM (see the last page of this manual), connect the wires to their 
respective terminals making sure that all the connections are firm and safe. 
4.4
Reinstall the cable clamp and wiring cover. 
Note: When connecting the wires of indoor and outdoor units, the power should be cut off. 
 
 
 
Step5: Connecting Refrigerant Pipe 
5.1 Unscrews the valve cover,  grasp and press it down gently to take it down(if the valve cover is 
applicable). 
5.2
Remove the protective caps from the end of valves. 
5.3 Take off the plastic cover in the pipe ports and check whether there is any sundry on the port of 
the connecting pipe and make ensure the port is clean. 
5.4 After align the center, rotate the flare nut of the connecting pipe to tighten the nut as tightly as 
possible by hand. 
5.5 Use a spanner hold the body of the valve and use a torque wrench to tighten the flare nut 
according to the torque values in the torque requirements table. 
(Refer to the torque requirements table on section INSTALLATION PRECAUTIONS) 
 
 
 
 
 
Terminal block 
Cable clamp 
Wiring cover 
Take down the valve cover 
connection pipes 
flare nuts 
 
 
 
 
Wiring 
diagram 
34 
EN - 29
 