Water Pressure; Error; Terminal - Daikin RoCon+ HP EHSX04P30D Manual De Instrucciones

Ocultar thumbs Ver también para RoCon+ HP EHSX04P30D:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 233
INFORMATION
Depending on the device type, the system configuration
and the version of the device software, individual informa-
tion parameters listed in
are displayed at another parameter level.
7.7.3

Water pressure

[→ Main menu → Information → Pressure]
Parameters
Setting range
Min / Max
Water pres-
0 - 4 bar
sure
Tab. 7-30 Parameter in menu: "Water pressure"
7.8

Error

[→ Main menu → Error]
Parameters
Setting range
Min / Max
Emergency
operation
No
Yes
Manual oper-
Inactive
ation status
Active
Temperature,
20 - 80 °C
manual oper-
ation
Tab. 7-31 Parameter in menu: "Error"
7.9

Terminal

[→ Main menu → Terminal]
Parameters
Setting range
Min / Max
Terminalad-
Off
ress
0 - 9
Bus - Scan
Off
On
Contr BM1/
BE1 #X
Mix Valve #X
Tab. 7-32 Parameter in menu: "Terminal"
Daikin RoCon+ HP
Daikin Controller RoCon+ HP
008.1444299_01 – 09/2018 – EN
Chap. 7.7
cannot be displayed or
The current water pressure is displayed in bar.
Emergency heating by backup heater or another external heat generator.
Yes: In the event of an error, emergency operation is automatically activ-
ated.
No: In the event of an error, emergency operation by manual activation
only.
Activation of the fixed feed temperature control (for diagnostic purposes).
Required feed temperature for manual operation.
Setting of the terminal ID of the control panel for system access. The set
value must be unique throughout the entire system. Confirmation of this
parameter with the rotary button effects a new initialisation of the control
unit.
All settings except "Off", authorise the user of the control panel to activate
the terminal function and thus to operate all RoCon system components
with a valid device ID.
No function
Control unit checks which RoCon devices are connected in the system via
CAN bus lines. Detected devices are displayed in the menu [→ Main menu
→ Terminal] with type and data bus ID (e.g. MM#8 = mixer module with
bus ID 8).
With a detected device only: Activation switches to the heat generator with
the bus ID X (see
Chap.
4.8, [BUS ID HS] parameter).
With a detected device only: Activation switches to the mixer module with
the bus ID X (see
Chap.
4.8, [Heating circuit assignment] parameter).
Description
Description
Description
7
Parameter settings
Factory
Incre-
Access
setting
ment
BE HF
-
0.1 bar
S
Factory
Incre-
Access
setting
ment
BE HF
-
E
-
E
50 °C
-
E
Factory
Incre-
Access
setting
ment
BE HF
Off
1
N
Off
-
E
-
-
E
Operating Instructions
S
E
E
E
E
E
E
47